Especificación
| Structure Of Inner Conductor(No./Mm) | Insulation Layer Thickness | Diameter Of Outer Insulation(Mm) | Thickness Of Sheath | Sheath | Max Resistance Of Conductor At 20℃(ω/100m) | |||
| Specified Value(Mm) | Mini Value(Mm) | Specified Value(Mm) | Mini Value(Mm) | Lower Limit(Mm) | Upper Limit(Mm) | |||
| 2×1/0.4 | 0.25 | 0.15 | 1.00±0.06 | 0.4 | 0.25 | 2.6 | 3.2 | 145.0 |
| 2×1/0.5 | 0.2 | 0.1 | 1.00±0.06 | 0.4 | 0.25 | 2.6 | 3.2 | 95.0 |
| 2×1/0.8 | 0.6 | 0.45 | 2.20±0.10 | 0.45 | 0.3 | 5.0 | 6.0 | 36.6 |
| 4×1/0.4 | 0.25 | 0.15 | 1.00±0.06 | 0.4 | 0.25 | 3.0 | 3.6 | 145.0 |
| 4×1/0.5 | 0.2 | 0.1 | 1.00±0.06 | 0.4 | 0.25 | 3.0 | 3.6 | 95.0 |
| 6×1/0.4 | 0.25 | 0.15 | 1.00±0.06 | 0.4 | 0.25 | 3.5 | 4.2 | 145.0 |
| 6×1/0.5 | 0.2 | 0.1 | 1.00±0.06 | 0.4 | 0.25 | 3.5 | 4.2 | 95.0 |
| 8×1/0.4 | 0.25 | 0.15 | 1.00±0.06 | 0.5 | 0.35 | 4.0 | 4.6 | 145.0 |
| 8×1/0.5 | 0.2 | 0.1 | 1.00±0.06 | 0.5 | 0.35 | 4.0 | 4.6 | 95.0 |
| Item | Performance Index |
| Tensile Strength Before Test Of Insulation Aging(Medium Value) | ≥12.5mpa |
| Tensile Strength After Test Of Insulation Aging | ≥10mpa |
| Elongation Rate At Break Before Test Of Insulation Aging | ≥125% |
| Elongation Rate At Break After Test Of Insulation Aging | ≥100% |
| Insulation Removability | Do Not Hurt Insulation And Conductor |
| Cold Bend Of Insulation | Not Crack |
| Item | Performance Index |
| Heat Impulse On Insulation | Not Crack |
| Insulation Dielectric Strength | 1500v, 1min Not Breakdown At 1500v, 1min |
| Test Of Insulation Resistance | 20℃≤200mω.Km/70℃≤0.3mω.Km |
| Broken, Mixture Wire Of Conductor(Continuity) | No Breakdown And Mixture |
| Voltage Withstand Of Final Wire | 2000v, 1min Not Breakdown At 2000v, 1min |
| Friction Resistance Of Logo | Friction Resistant, Legible |
CONTACT US>
NO.82 Tianzhu Street, Qingshan Industry Zone, Linan Hangzhou 311305,China
Tel:+86-571-61078809
Tel:+86-571-63785516
Email:
info@xfcable.com
sales@xfcable.com